HUBUNGAN ANTARA UMUR DAN INTENSITAS CAHAYA LAS DENGAN KELELAHAN MATA PADA JURU LAS PT. X DI KABUPATEN GRESIK
Downloads
Welding occurs much hazard especially toward welders eyestrain. The Objective of study was to analyzed relation between age and eyestrain and also weld luminous intensity and eyestrain at welders of PT. X in District of Gresik. Research was carried out by cross sectional and observational study. Subjects were 20 welders of PT. X in District of Gresik. Data collecting was carried out by interview, measurement instrument, and examination. The independent variables were age and weld luminous intensity, and the dependent variable was eyestrain. Spearman Test was used to correlate between age and eyestrain. Pearson Product Moment Test was used to correlate between weld luminous intensity and eyestrain. According to the results, there was significant correlation between age and eyestrain (p = 0,007). There are more eyestrains will be occurred in older age. Result also showed that there was significant correlation between weld luminous intensity and eyestrain (p = 0,023). High exposure of weld luminous intensity will occurs contrast so that eyes needs much effort to adapt it. Light of weld contain UV light, visible light, and infrared radiation. In conclusion, there was significant correlation between age and eyestrain. And also, there was significant correlation between weld luminous intensity and eyestrain. Welders must use face shield depend on types of welding and company should held eyes examination to welders routinely.
Keywords: age, weld luminous intensity, eyestrain
Andryansyah. 2000. Kesehatan dan Keselamatan Kerja Pengelasan Dalam Ruang Terbatas. Buletin Keselamatan Statuta, Vol. 1, 52–55.
Angelina, C. dan K. Oginawati. Paparan Fisis Pencahayaan terhadap Mata dalam Kegiatan Pengelasan (Studi Kasus: Pengelasan di Jalan Bogor). http://www.ftsl.itb.ac.id/kk/ teknologi_pengelolaan_lingkungan/wp-content/ uploads/2010/10/PI-EH6-Cory-Angelina-
pdf (Sitasi 26 Desember 2014) Fitriadi, R. 2008. Penentuan Prioritas Alternatif
Pengelasan Pada Body Welding Minibus. Simposium Nasional RAPI VII 2008, I-66 - I-73.
Fowler, B. 2003. Functional and Biological Markers of Aging. Dalam: Klatz, R. 2003. Anti-Aging Medical Therapeutics, Vol. 5. Chicago: The A4M Publications.
Grainger. Faceshield Protection. https://www. grainger.com/content/qt-face-shield-protection-373 (Sitasi 24 Januari 2016)
Grandjean, E. 1988. Fitting The Task to The Man: A Textbook of Occupational Ergonomics 4th Edition. London: Taylor & Francis.
Hall, S. Safety and Ergonomics in Welding: Need For A New Generation Of Welding Helmet Suited To Pulsed Welding Arcs. http:// supporting-paa.wikispaces.com/file/detail/ Pulsed+welding+eye+strain.pdf (Sitasi 12 Januari 2016)
Hammond Jr., B.R., Fletcher L.M.,dan J.G. Elliott. 2013. Glare Disability, Photostress Recovery, and Chromatic Contrast: Relation to Macular Pigment and Serum Lutein and Zeaxanthin. Investigative Ophthalmology & Visual Science, Vol. 54, No. 1.
Hanum, I.F. 2008. Efektivitas Penggunaan Screen pada Monitor Komputer untuk Mengurangi Kelelahan Mata Pekerja Call Centre di PT. Indosat
Heilig, P., E. Rozanova, J. Godnic-Cvar. Retinal Light Damage. http://www.lightmare.org/docs/ Retinal_Light_Damage_RLD2529_en.pdf (Sitasi 12 Januari 2016)
Hunter, J.J., J.I.W. Morgan, W.H. Merigan, D.H. Sliney, J.R. Sparrow, dan D.R. Williams. 2012. The Susceptibility of The Retina To Photochemical Damage from Visible Light. Progress in Retinal and Eye Research 31 28e42.
Ito, Y., M. Horiguchi, Y., Miyake., S. Awaya. 1997. Extrafoveal Photostress Recovery Testing With a Scanning Laser Ophthalmoscope. Jpn J Ophthalmol 1997; 41: 255–259.
Kementerian Tenaga Kerja. 1999. Keputusan Menteri Tenaga Kerja Nomor 51 tahun 1999 Tentang Nilai Ambang Batas Faktor Fisika di Tempat Kerja. Jakarta: Kementerian tenaga Kerja.
Marsida, A.Y. 1999. Photostress Recovery Test pada Penderita Hipertensi. Tesis. Medan, Universitas Sumatera Utara.
Omokhua, P.O., O.G. George. 2010. Photostress Recovery Time Among Nigerians. JNOA, Vol. 16, 16–20.
Santoso, G. 2004. Manajemen Keselamatan dan Kesehatan Kerja. Jakarta: Prestasi Pustaka. Sedarmayanti. 2011. Tata Kerja dan Produktivitas Kerja. Bandung: CV Mandar Maju.
Setiawan, D. 2015. Faktor yang Berhubungan dengan Kelelahan Mata pada Juru Las di PT. X. Skripsi. Surabaya, Universitas Airlangga.
Simanjuntak, L.F. 2007. Pengaruh dan Hubungan Umur Terhadap Kapasitas Vital pada Pria Dewasa Normal. Skripsi. Bandung, Universitas Kristen Maranatha.
Siswanto, A. 1994. Bahaya Las. Balai Hiperkes dan Keselamatan Kerja Jawa Timur Departemen Tenaga Kerja.
Stringham, J.M., P.V. Garcia, P.A. Smith, L.N. McLin, dan B.K. Foutch. 2011. Macular Pigment and Visual Performance in Glare: Benefits for Photostress Recovery, Disability Glare, and Visual Discomfort. Investigative Ophthalmology & Visual Science, Vol. 52, No. 10.
Suharyanto, F.X., E. Safari. 2010. Asthenopia Pada Pekerja Wanita Di Call Centre-X. Buletin Penelitian Kesehatan Vol. 38, No. 3, 119-130.
Suma'mur. 2009. Higiene Perusahaan dan Kesehatan Kerja (Hiperkes). Jakarta: CV Sagung Seto. Tarwaka, B., L. Sudiajeng. 2004. Ergonomi Untuk Keselamatan, Kesehatan Kerja dan Produktivitas. Surakarta: UNIBA Press.
In order to be accepted and published by The Indonesian Journal of Occupational Safety and Health, Author(s) who submit an article should complete all the review process. The copyright of received articles assigned to the The Indonesian Journal of Occupational Safety and Health and Department of Safety and Health, Universitas Airlangga as publishers of the journal. The intended copyright includes the rights to publish articles in various forms (including reprints).
The Editorial Team of The Indonesian Journal Of Occupational Safety and Health and Department of Safety and Health strive to ensure that no errors occur in the articles that have been published, both data errors and statements in the article.
Users of this website will be licensed to use materials from this website following the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License. No fees charged. Please use the materials accordingly.
------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Attribution ” You must give appropriate credit, provide a link to the license, and indicate if changes were made. You may do so in any reasonable manner, but not in any way that suggests the licensor endorses you or your use.
NonCommercial ” You may not use the material for commercial purposes.
ShareAlike ” If you remix, transform, or build upon the material, you must distribute your contributions under the same license as the original.