Intravascular ultrasonography (IVUS) has an important role as a complimentary diagnostic tool in percutaneous coronary intervention procedure. IVUS provides valuable information regarding coronary vessel lumen and dimension and also plaque burden and its characteristic. The main use of IVUS in PCI is to guide the choose of interventional strategies to optimize stent deployment. Since drug eluting stent (DES) has promised to decrease the incidence in stent restenosis and stent thrombosis than bare metal stent, but neither the suboptimal results nor the complication after stenting with DES is still high. Thus, optimization of stent deployment under IVUS guidance is important in cases to decrease stent failure after PCI procedure, as well as to decrease complication rate after stenting in order to decrease mortality rate caused by coronary artery disease. We present here the use of IVUS guidance in a 43 and 46 year-old man underwent PCI.

Keywords

Intravascular ultrasonography percutaneous coronary intervention stent deployment

Article Details

How to Cite
Oktaviono, Y. H., & Putri, A. Y. (2019). Case Report: The Role of Intravascular Ultrasonography in Patients Underwent Percutaneous Coronary Intervention. Folia Medica Indonesiana, 55(4), 311–321. https://doi.org/10.20473/fmi.v55i4.24517

References

  1. Boudi B (2015). Coronary artery atherosclerosis. Available from: http://emedicine.medscape.com/arti-cle/153647. Accessed March 12, 2016
  2. Dharma S, Juzar DA, Firdaus I, Soerianata, Wardeh AJ, Jukema JW (2012). Acute myocardial infarction system of care in the third world. Neth Heart J 20, 254-259
  3. Im E, Kim JS, Hong MK (2015). Intravascular ultrasound as an adjunct tool for angiographycally intermediate lesions and complex coronary interventions: patient selection and perspective. Vasc J Diag 3, 41-51
  4. Kovarnik T, Horak J (2012). IVUS Guided PCI. In: Honda Y, editor. Intravascular ultrasound. InTech
  5. Lin CP, Honye J, Chang CJ, Kuo CT (2011). Clinical application of intravascular ultrasound in coronary artery disease: an update. Acta Cardiol Sin 27, 1-3
  6. Liu X, Doi H, Maehara A, Mintz GS, Ribamar J, Sano K, Weisz G, Dangas GD, Lansky AJ, Kreps EM, Collins M, Fahy M, Stone GW, Moses JW, Leon MB, Mehran R (2009). A volumetric intravascular ultrasound comparison of early drug-eluting stent thrombosis versus restenosis. J Am Coll Cardiol Intv 2, 428-34
  7. Lotfi A, Jeremias A, Fearon WF, Feldman MD, Mehran R, Messenger JC, Grines CL, Dean LS, Kern MJ, Klein LW (2013). Expert consensus statement on the use of fractional flow reserve, intravascular ultrasound, and optical coherence tomography: A consensus statement of the society of cardiovascular angiography and interventions. Catheter Cardiovasc Interv 29, 741-752
  8. Nissen SE, Yock P (2001). Intravascular ultrasound novel pathophysiological insights and current clinical applications. Circulation 103, 604-616
  9. Rogacka R, Latib A, Colombo A (2009). IVUS-guided stent implantation to improve outcome: a promise waiting to be fulfilled. Current Cardiology Review 5, 78-86
  10. Waksman R, Kitabata H, Prati F, Albertucci M, Mintz GS (2013). Intravascular ultrasound versus optical coherence tomography guidance. Am J Cardiol 62, 32-40
  11. Yoon HJ, Hur SH (2012). Optimization of stent deployment by intravascular ultrasound. Korean J Intern Med 27, 30-38