Mandibular Magnet Retained Complete Overdenture
Downloads
Background: Complete denture in the lower jaw often has problems. The entire loss of the mandibular teeth often has a large resorption, so it is difficult to obtain retention and stability. Purpose: To report mandibular magnet retained complete overdenture is can increase retention and stability in the lower jaw. Case: A 60-year-old man came to the Prosthodontics Clinic of RSGM Airlangga University with complaints of the old complete denture that made by previous dentist, is often unstable while talking and chewing, so the patient feel uncomfortable. The denture has been used for approximately four years. Therefore the patient wants to make a new complete denture. Case Management: PFM crown removed and 31,32,33,41,43 are treated with root canal treatment. Magnet keepers are fabricated on teeth 33,43, and metal copings are fabricated on teeth 31,32,41. The complete lower denture is attached to the magnet. Acrylic material denture are chosen. Discussion: Overdenture is a complete or partial denture that is placed above the tooth structure or the root of the original tooth which is the support of the denture. Overdenture treatment can maintain ridge height, reduced load of supporting elements, and avoid mucosal irritation. It's necessary to add retention in the form of magnets to the teeth 33 and 43 to get good retention and stability. Conclusion: Mandibular magnet retained complete overdenture is can increase retention and stability in the lower jaw so that the patient feels satisfied and comfortable because the dentures are more retentive and stable.
Minoru Ai, Shiau Y. New Magnetic Application in Clinical Dentistry. Tokyo. .2004.
Rilley MA, Anthony DW, Ivor RH. Magnet in ProstheticDentistry. J ProsthetDent. 2001;86 (2); Pp.137-42.
Lord JL, Teel S. Overdenture : patients selection, using coping, and evaluation. J Prosthet Dent. 1995; 32: 41-51.
Toolson LB, Talor TD. A 10 years report of a longitudinal recall of overdenture patients. J Prosthet Dent 1989; 62 : 179-81.
Basker RM, Harrison A, Ralph JP. Overdenture in general dental practice. Br Dent J .1993; 154: 285.
Brewer AA, Morrow RM. 1980. Overdenture 2 ed. The C.V Mosbby Co; 100-35, 208-10,222-45,341-7,376-9.
Dharma U. 2016. Gigi Tiruan Implan dan Overdenture. CV. Menara Intan : p. 60-80.
Ai M, Shiau YY. 2004. New magnetic application in clinical dentistry. Quintessence Publ Co. Ltd, Tokyo. p.30.
Alani A, Maglad A, Nohl F. 2011.The Prosthetic Management of Gingival Aesthetics. Br. Dent. J. 210:63-69.
Rutkunas V, Mizutani H, Takahashi H. Influence of attachment wear on retention of mandibular overdenture. J Oral Rehabil. 2007;34(1):41-51.
This is an open access journal, and articles are distributed under the terms of the Creative Commons Lisence, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
Copyright notice:
IJDM by UNAIR is licensed under a Creative Commons Atribusi 4.0 Internasional.
- The journal allows the author to hold the copyright of the article without restrictions.
- The journal allows the author(s) to retain publishing rights without restrictions.
- The legal formal aspect of journal publication accessibility refers to Creative Commons Attribution (CC BY)