Forces achieved by different material and type of intrusion arches applied in different horizontal levels
Downloads
Background: Intrusion is one of the most needed movements in orthodontics. It is possible to achieve this with arch wires, miniscrews, and bite-blocks. Purpose: This in vitro study aimed to evaluate forces achieved by different types of intrusion arches made of different materials and anchored in two different horizontal levels by either miniscrews or molar teeth. Methods: An upper jaw typodont was applied different types of intrusion arches: intrusion and utility arches, made of different materials (nitinol, beta III titanium, stainless steel) and different wire sizes (0.016” x 0.022” and 0.017” x 0.025”) to the incisors, both anchoring from molars and miniscrews respectively. Each application was measured by a Correx gauge. Each wire was applied to both the auxiliary slot of the triple tube and the slot in the head of the miniscrew. One-way analysis of variance (ANOVA), Tukey's HSD test, and a paired two-sample t-test were used to analyze the data. Results: In the intrusion arches, the main effect of the material was found to be statistically significant on force values (p = 0.034) while the main effect of the size was not found statistically significant on force values (p = 0.083). In the utility arches, both the main effect of the material (p = 0.067) and the size (p = 0.140) were not found to be statistically significant on force values. Conclusion: Regardless of the anchorage unit level and size, nitinol was the material that applied the lowest forces among all materials. The material is the most effective factor in the force generated, while the anchorage unit level is the least.
Downloads
Parrini S, Rossini G, Castroflorio T, Fortini A, Deregibus A, Debernardi C. Laypeople's perceptions of frontal smile esthetics: A systematic review. Am J Orthod Dentofac Orthop. 2016; 150(5): 740–50. doi: https://doi.org/10.1016/j.ajodo.2016.06.022
Tosun H, Kaya B. Effect of maxillary incisors, lower lip, and gingival display relationship on smile attractiveness. Am J Orthod Dentofac Orthop. 2020; 157(3): 340–7. doi: https://doi.org/10.1016/j.ajodo.2019.04.030
Syahdinda MR, Nugraha AP, Triwardhani A, Noor TNE binti TA. Management of impacted maxillary canine with surgical exposure and alignment by orthodontic treatment. Dent J. 2022; 55(4): 235–9. doi: https://doi.org/10.20473/j.djmkg.v55.i4.p235-239
Tallo FR, Narmada IB, Ardani IGAW. Maxillary anterior root resorption in Class II/I malocclusion patients post fixed orthodontic treatment. Dent J. 2020; 53(4): 201–5. doi: https://doi.org/10.20473/j.djmkg.v53.i4.p201-205
Al Taki A, Hamdan AM, Mustafa Z, Hassan M, Abu-Alhuda S. Smile esthetics: Impact of variations in the vertical and horizontal dimensions of the maxillary lateral incisors. Eur J Dent. 2017; 11(04): 514–20. doi: https://doi.org/10.4103/ejd.ejd_351_16
Drummond S, Capelli J. Incisor display during speech and smile: Age and gender correlations. Angle Orthod. 2016; 86(4): 631–7. doi: https://doi.org/10.2319/042515-284.1
Hamdan AM, Lewis SM, Kelleher KE, Elhady SN, Lindauer SJ. Does overbite reduction affect smile esthetics? Angle Orthod. 2019; 89(6): 847–54. doi: https://doi.org/10.2319/030819-177.1
Goel P, Tandon R, Agrawal KK. A comparative study of different intrusion methods and their effect on maxillary incisors. J Oral Biol Craniofacial Res. 2014; 4(3): 186–91. doi: https://doi.org/10.1016/j.jobcr.2014.11.007
de Almeida MR, Marçal ASB, Fernandes TMF, Vasconcelos JB, de Almeida RR, Nanda R. A comparative study of the effect of the intrusion arch and straight wire mechanics on incisor root resorption: A randomized, controlled trial. Angle Orthod. 2018; 88(1): 20–6. doi: https://doi.org/10.2319/06417-424R
Kaushik A, Sidhu MS, Grover S, Kumar S. Comparative evaluation of intrusive effects of miniscrew, Connecticut intrusion arch, and utility intrusion arch – An in vivo study. J Pierre Fauchard Acad (India Sect. 2015; 29(4): 69–76. doi: https://doi.org/10.1016/j.jpfa.2016.01.001
Gupta N, Tripathi T, Rai P, Kanase A, Neha. A comparative evaluation of bite opening by temporary anchorage devices and Connecticut intrusion arch: An in vivo study. Int J Orthod Rehabil. 2017; 8(4): 129–35. doi: https://doi.org/10.4103/ijor.ijor_28_17
Sharma S, Vora S, Pandey V. Clinical evaluation of efficacy of CIA and CNA intrusion arches. J Clin Diagn Res. 2015; 9(9): ZC29-33. doi: https://doi.org/10.7860/JCDR/2015/11878.6465
Atalla AI, AboulFotouh MH, Fahim FH, Foda MY. Effectiveness of orthodontic mini-screw implants in adult deep bite patients during incisor intrusion: A systematic review. Contemp Clin Dent. 2019; 10(2): 372–81. doi: https://doi.org/10.4103/ccd.ccd_618_18
Kalra S, Tripathi T. Miniscrew supported Burstone intrusion arch. Int J Orthod Milwaukee. 2015; 26(1): 25–6. pubmed: https://pubmed.ncbi.nlm.nih.gov/25881380/
Kumar P, Datana S, Londhe SM, Kadu A. Rate of intrusion of maxillary incisors in Class II Div 1 malocclusion using skeletal anchorage device and Connecticut intrusion arch. Med J Armed Forces India. 2017; 73(1): 65–73. doi: https://doi.org/10.1016/j.mjafi.2015.10.006
Schwertner A, Almeida RR de, Gonini Jr A, Almeida MR de. Photoelastic analysis of stress generated by Connecticut Intrusion Arch (CIA). Dental Press J Orthod. 2017; 22(1): 57–64. doi: https://doi.org/10.1590/2177-6709.22.1.057-064.oar
Caldas SGFR, Ribeiro AA, Simplício H, Machado AW. Segmented arch or continuous arch technique? A rational approach. Dental Press J Orthod. 2014; 19(2): 126–41. doi: https://doi.org/10.1590/2176-9451.19.2.126-141.sar
Kanuru R, Azaneen M, Narayana V, Kolasani B, Indukuri R, Babu F. Comparison of canine retraction by in vivo method using four brands of elastomeric power chain. J Int Soc Prev Community Dent. 2014; 4(4): S32-7. doi: https://doi.org/10.4103/2231-0762.144586
Proffit W, Fields H, Larson B, Sarver D. Contemporary orthodontics. 6th ed. Philadelphia: Mosby; 2018. p. 256. web: https://www.elsevier.com/books/contemporary-orthodontics/proffit/978-0-323-54387-3
Jian F, Lai W, Furness S, McIntyre GT, Millett DT, Hickman J, Wang Y. Initial arch wires for tooth alignment during orthodontic treatment with fixed appliances. Cochrane Database Syst Rev. 2013; (4): CD007859. doi: https://doi.org/10.1002/14651858.CD007859.pub3
Copyright (c) 2024 Dental Journal
This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.
- Every manuscript submitted to must observe the policy and terms set by the Dental Journal (Majalah Kedokteran Gigi).
- Publication rights to manuscript content published by the Dental Journal (Majalah Kedokteran Gigi) is owned by the journal with the consent and approval of the author(s) concerned.
- Full texts of electronically published manuscripts can be accessed free of charge and used according to the license shown below.
- The Dental Journal (Majalah Kedokteran Gigi) is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License