DETERMINATION OF LOCAL DIAGNOSTIC REFERENCE LEVEL (LDL) PEDIATRIC PATIENTS ON CT HEAD EXAMINATION BASED ON SIZE-SPECIFIC DOSE ESTIMATES (SSDE) VALUES
Downloads
Background: CT Scan provides the biggest contribution in receiving radiation doses in patients. Especially in pediatric patients or children. Local DRL (Diagnostic Reference Level) is an effort to optimize radiation for patients in every health facility. During this time the LDRL value is determined from the CTDIvol displayed from the CT Scan workstation. However, CTDI has a weakness which is irrelevant for wide-beam CT and is only a tool output dose, not paying attention to patient size. SSDE is a dose correction based on the patient's geometry. Purpose: This study aims to determine the estimation of pediatric patient dose profiles on head CT scan based on SSDE values to determine LDRL. Method: The study was conducted by collecting data on pediatric patient doses with an age range of 0-1 years, 2-5 years and 6-10 years who underwent a head CT scan within the period from July to December 2017. The samples were measured lateral and anterior-posterior diameter for determine the correction factor. The results of the CTDIvol record and conversion factor will determine the SSDE value. The third quartile data from SSDE is specified as LDRL. The SSDE value in the three groups shows the same trend which is smaller than the CTDIvol value. The correction of the factor gives estimates of doses received by patients reduced by 2.6%, 8.5% and 20% respectively for ages 0-1 years, 2-5 years and 6-10. Acceptance of patient doses is influenced by tube tension, filament current, rotation time, scan length, number of phases and pitch. Conclusion: From the results of the SSDE value, DRL values can be determined for the age group 0-1 years, 2-5 years and 6-10 years respectively 23,1±1,5 mGy, 24,3± 1,8 mGy and 27, 5± 10,5mGy.
Abdullahi, S.M., Kamal, I.L., Ahidjo, A., Nwobi, I.C. 2016. Diagnostic Reference Level for Patients Investigated with Abdomen Computed Tomography at University of Maiduguri Teaching Hospital. The African Review of Physics. Vol.11(10).
Amando, A.M. 2016. Studi Komparasi Pengaruh Penurunan kV Terhadap Dosis dan Kualitas Gambar Dari beberapa Modalitas CT Scan Multidetektor. Skripsi. Fakultas Vokasi Universitas Airlangga
American Association of Physicists in Medicine. 2011. Size−Specific Dose Estimates (SSDE) in Pediatric and Adult Body CT Examinations. AAPM Report No. 204.
Anam, C., Haryanto, F., Widita, R., Arif, I., Dougherty, G. 2016. A fully automated calculation of size-specific dose estimates (SSDE) in thoracic and head CT examinations. Journal of Physics Conference Series, Vol 694. Conference 1.
Anam, C., Haryanto, F., Widita, R., Arif, I., Dougherty, G. 2017. The Evaluation of the Effective Diameter (Deff) Calculation and its Impact on the Size- Specific Dose Estimate (SSDE). Atom Indonesia Vol 43(1).
Berrington de Gonzales, A., Mahesh, M., Kim, K.P. 2009. Projected Cancer from Computed Tomographic Scan Performed in United States in 2007. Archive in Internal Medicine. Vol 192(22). Pp. 2071-2077.
Boniface, Moifo, Moulion, Jean, R., Guena, Mathorin, N., Ndah, Tierry N., Samba, Richard N., Simo, Agustin. 2017. Diagostic Reference Level of Adult Ct-Scan Imaging in Cameroon: A pilot Study fo Four Commonest Ct-Protokol in Five Radiology Departements. Scientific Reserch Publising 2017. Vol 7. Pp.1-8
Fauziyah, A. 2016. Pengaruh Variasi Rotation Time Terhadap Nilai DLP (Dose Length Product) Dan Image Noise Pada Pesawat MSCT 128 Slice. Skripsi. Fakultas Vokasi Universitas Airlangga.
Galanski, M., Nagel, H.D., Stamn, G. 2007. Paediatric Ct Exposure Practice in The Federal Republic Germany: Result of a Nationwide Survey in 2005-2006. Medizinische Hochschule Hannover.
Imai, R., Miyazaki, O., Horiuchi, T., Kurosawa, H., Nosaka, S. 2014. Local diagnostic reference level based on size-specificdose estimates: Assessment of pediatric abdominal/pelvic computed tomography at a Japanese national children's hospital. Pediatric Radiology. Vol.45. Pp.345-353.
International Commission on Radiological Protection (ICRP). 2000. Managing Patirnt Dose in Computed Tomography. ICRP Publication 87
Janbabanezhad, T.A., Shabestani-Monfared, A., Deevband, M.R., Andi, R., Nabahati, M. 2015. Dose Assessment in Computed Tomography Examination and establishment of Local Diagnostic Reference Levels in Mazandaran, Iran. Journal Biomedical Physics and Engeenering. Vol.5(4). Pp. 177-184.
Kalra, M.K., Woisetschläger, M., Dahlström, N., Singh, S., Digumarhty, Do S, Pien, H., Quick, P., Schmidt, B., Sedlmair, M., Shepard, J.A., Persson, A. 2013. Sinogram-affirmed iterative reconstruction of low-dose chest CT: effect on image quality and radiation dose. AJR. Vol.20l. Pp.235–244
Mathews, J.D., Forsythe, Anna, V., Brady, Z., Martin W Butler, Stacy K Goergen, Graham B Byrnes, Graham G Giles, Anthony B Wallace, Philip R Anderson, Tenniel A Guiver, Paul McGale, Timothy M Cain, James G Dowty, Adrian C Bickerstaffe, Sarah C Dar. Cancer risk in 680 000 people exposed to computed tomography scans in childhood or adolescence: data linkage study of 11 million Australians. BMJ.
Matsubara, K. 2017. Computed Tomography Dosimetry: From Basic to State-of- the-art Techniques. Medical PhysicsInternational Journal. Vol 5 (1). Pp.61-67.
Naja, M., Deevband, R.M., Ahmadi, M., Kardan, M.R. 2015. Establishment of Diagnostic Reference Levels for Common multislice Derevtor Computed Tomography examination in Iran. Australasian Physical & Engineering Science in Medicine. Vol. 38(4).Pp.603-609
Puput, K. 2014. Pengaruh Variasi Faktor Eksposi (Tegangan Tabung Dan Arus Waktu) Serta Pitch Terhadap Computed Tomography Dose Index (CTDI) Di Udara Menggunakan CT Dose Profiler. Youngster Physics Journal. Vol.3. Pp.363-372
Rahadhy, S., Intanung, S. 2014. Peranan Radiasi Pasien Pada Pemeriksaan CT-Scan. Prosiding Seminar Kesehatan Nuklir 2014; Jakarta, Indonesia.
Rumboldt, Z., W. Huda, J.W., All. 2009. Review of Portable CT with Assessment of a Dedicated Head CT Scanner. American Journal of Neuroradiology. Vol.30(9). Pp.1630-1636.
Shrimpton, P.C., Hillier, M.C., Lewis, M.A., Dunn, M. 2005. Doses from Computed Tomography (CT) Examination in the UK: 2003 review, Report NRPB-W67. Chilton. UK: National Radiological Protection Board.
Soderberg, M. 2010. Automatic Exposure control in computed tomography-an evaluation of system from different manufacturers. 2010 Automatic Exposure control in computed tomography-an evaluation of system from different manufacturers. Acta Radiologica 51 (6).Pp.625-634
Suri, J.S., Kathuria, C.N. 2011. Atherosclerosis Disease Management. Biomedical Technologist. Inc. United States of America.
Susanto, A. 2014. Peranan CT Scan Kepala dalam Diagnosis Nyeri Kepala Kronis. CDK. 41
Tsapaki, V., Rehani, M. 2007. Dose Management in CT Facility; Biomedical Imaging and Interventional Journal Review Article. Vol.3(2): E43
Verdun, F.R., Gutierrez, D., Vader, J.P., Aroua, A., Alamo-Maestre, L.T., Bochud, F., et all. 2008. CT Radiation Dose in children: a survey to establish age-based diagnostic Refrence Levels in Switzerland. European Radiology. Vol 18.Pp.1980-1986.
Copyright (c) 2019 Journal Of Vocational Health Studies
This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License.
- The authors agree to transfer the transfer copyright of the article to the Journal of Vocational Health Studies (JVHS) effective if and when the paper is accepted for publication.
- Legal formal aspect of journal publication accessibility refers to Creative Commons Attribution-NonCommercial-ShareAlike (CC BY-NC-SA), implies that publication can be used for non-commercial purposes in its original form.
- Every publications (printed/electronic) are open access for educational purposes, research, and library. Other that the aims mentioned above, editorial board is not responsible for copyright violation.
Journal of Vocational Health Studies is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License